NSN: 5925-01-068-2506

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    7.500 ounces

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Center To Center Distance Between Terminals Parallel To Length

    1.518 inches minimum and 1.592 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.718 inches minimum and 0.782 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.718 inches minimum and 0.782 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Case Material

    plastic

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Width

    2.218 inches minimum and 2.282 inches maximum

  • Terminal Type And Quantity

    6 solder stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.628 inches minimum and 1.682 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Mounting Surface To Terminal End Distance

    2.168 inches minimum and 2.232 inches maximum

  • Boss Height

    0.098 inches minimum and 0.162 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Length

    1.938 inches minimum and 2.032 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...