NSN: 5925-01-069-3442

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.539 inches minimum and 2.683 inches maximum

  • Pole Quantity

    2

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Switch Terminal Type

    turret

  • Iii Unpackaged Unit Weight

    8.500 ounces

  • Thread Series Designator

    unc

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    external at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Current Rating And Type In Amps

    1.0 dc

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Terminal Type And Quantity

    4 threaded stud

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...