NSN: 5925-01-070-6244

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.492 inches minimum and 2.331 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Features Provided

    sliding bar interlock

  • Reset Method

    manual

  • Switch Terminal Type

    turret

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and hermetically sealed

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    12.750 ounces

  • Terminal Type And Quantity

    8 threaded stud

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Switch Location And Position Designation

    external at pole one

  • Frequency In Hertz

    50.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Manual Actuator Type And Quantity

    4 toggle

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Pole Quantity

    4

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...