NSN: 5925-01-072-3870

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Frequency In Hertz

    60.0 all locations

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.980 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    3.073 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and

  • Case Material

    plastic

  • Body Style

    8c multipole-multiple actuator type

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Boss Height

    0.166 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.980 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.760 inches maximum

  • Body Width

    3.062 inches maximum

  • Body Width

    3.042 inches minimum and

  • Body Length

    3.729 inches maximum

  • Body Length

    3.709 inches minimum and

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Iii Unpackaged Unit Weight

    1.770 pounds

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 maximum at 200 pct all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct and

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Iii Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Boss Height

    0.146 inches minimum and

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...