NSN: 5925-01-074-4329
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
0.686 inches nominal
-
Thread Quantity Per Inch
27
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc single location
-
Trip Release Method
thermal single location
-
Reset Method
manual
-
Actuator Function
reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Ambient Temp Rating
70.0 deg fahrenheit nominal single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Style
1a single pole type
-
Bushing Length
0.390 inches nominal
-
Body Length
0.750 inches nominal
-
Body Width
0.450 inches nominal
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
2.070 inches nominal
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 24.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push button
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 40.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Special Features
current rating marked on item button
-
Frequency In Hertz
400.0
-
Thread Series Designator
uns