NSN: 5925-01-075-9491
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Unpackaged Unit Weight
12.750 ounces
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
2.5 ac
-
Body Width
2.240 inches minimum and 2.260 inches maximum
-
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.523 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic-hydraulic all locations
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Switch Terminal Type
tab, solder lug
-
Fragility Factor
moderately rugged
-
Terminal Type And Quantity
6 threaded stud
-
Case Material
plastic
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct all locations and 8.500 minimum at 150 pct all locations and 0.600 minimum at 400 pct all locations and 13.000 maximum at 200 pct all locations and 30.000 maximum at 150 pct all locations and 2.000 maximum at 400 pct all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Ultimate Trip Time Per Pole In Seconds
80.000 maximum all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
50.0 all locations
-
Switch Location And Position Designation
external at pole one
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Nominal Thread Size
0.138 inches
-
Mounting Facility Type And Quantity
6 threaded hole