NSN: 5925-01-075-9491

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    12.750 ounces

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac

  • Body Width

    2.240 inches minimum and 2.260 inches maximum

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.523 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 8.500 minimum at 150 pct all locations and 0.600 minimum at 400 pct all locations and 13.000 maximum at 200 pct all locations and 30.000 maximum at 150 pct all locations and 2.000 maximum at 400 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Ultimate Trip Time Per Pole In Seconds

    80.000 maximum all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    50.0 all locations

  • Switch Location And Position Designation

    external at pole one

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Mounting Facility Type And Quantity

    6 threaded hole

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...