NSN: 5925-01-076-6377
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Auxiliary Switch Function And Quantity
2 alarm
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.718 inches minimum and 0.782 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.718 inches minimum and 0.782 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Unpackaged Unit Weight
5.000 ounces
-
Switch Contact Arrangement
single pole, double throw
-
Body Length
1.968 inches minimum and 2.032 inches maximum
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Length
1.528 inches minimum and 1.592 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc
-
Arc Quenching Method
magnetic blowout
-
Body Width
1.468 inches minimum and 1.532 inches maximum
-
Boss Height
0.098 inches minimum and 0.162 inches maximum
-
Switch Location And Position Designation
internal at each pole
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Manual Actuator Type And Quantity
2 toggle
-
Mounting Surface To Terminal End Distance
2.233 inches minimum and 2.297 inches maximum
-
Switch Terminal Type
quick disconnect, male
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.628 inches minimum and 1.692 inches maximum
-
Terminal Type And Quantity
4 quick disconnect, male
-
External Actuator Linkage Arrangement
one and two linked
-
Case Material
plastic