Technical Characteristics

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Width

    1.530 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.725 inches minimum and 0.735 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.725 inches minimum and 0.735 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.145 inches minimum and 0.155 inches maximum

  • Mounting Surface To Terminal End Distance

    1.841 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.935 inches minimum and 1.945 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac first location

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    400.0 first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc second location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct second location and 6.000 maximum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 8.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Unpackaged Unit Weight

    3.600 ounces

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...