NSN: 5925-01-079-7295

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.745 inches minimum and

  • Mounting Surface To Terminal End Distance

    1.885 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Frequency In Hertz

    60.0 single location

  • Iii Unpackaged Unit Weight

    5.100 ounces

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Length

    2.015 inches maximum

  • Body Width

    0.755 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.665 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches minimum and

  • Boss Height

    0.135 inches maximum

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Length

    1.985 inches minimum and

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...