NSN: 5925-01-080-1768

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    relay trip fourth location

  • Body Length

    5.844 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    4

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • Mounting Facility Type And Quantity

    8 slot

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 125.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Unpackaged Unit Weight

    2.438 pounds

  • Boss Height

    0.218 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip third location

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Mounting Slot Width

    0.138 inches nominal

  • Internal Trip Release Configuration

    series trip second location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Body Width

    4.128 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Terminal Type And Quantity

    10 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...