NSN: 5925-01-080-9982

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct all locations

  • Switch Terminal Type

    tab, solder lug

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    2.250 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Body Length

    2.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.130 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 milliamperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole three

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    6.600 ounces

  • Terminal Type And Quantity

    6 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...