Technical Characteristics

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Style

    multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    0.906 inches minimum and 0.968 inches maximum

  • Case Material

    metal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    2 push-pull

  • Frequency In Hertz

    400.0 all locations

  • Mounting Surface To Terminal End Distance

    2.015 inches minimum and 2.077 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.405 inches minimum and 1.467 inches maximum

  • Body Length

    1.781 inches minimum and 1.843 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.781 inches minimum and 1.843 inches maximum

  • Body Width

    1.875 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations and 250.0 amperes dc all locations

  • Trip Release Method

    thermal all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations and 3000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.906 inches minimum and 0.968 inches maximum

  • Special Features

    parallel connecting bar accross terminas

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations and 28.0 dc all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Fragility Factor

    moderately rugged

  • Actuator Function

    reset

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...