NSN: 5925-01-085-5526
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip all locations
-
Terminal Type And Quantity
4 tab w/screw
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Body Style
multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Width
0.906 inches minimum and 0.968 inches maximum
-
Case Material
metal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Inclosure Protection Type For Which Designed
general purpose
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Manual Actuator Type And Quantity
2 push-pull
-
Frequency In Hertz
400.0 all locations
-
Mounting Surface To Terminal End Distance
2.015 inches minimum and 2.077 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.405 inches minimum and 1.467 inches maximum
-
Body Length
1.781 inches minimum and 1.843 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.781 inches minimum and 1.843 inches maximum
-
Body Width
1.875 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations and 250.0 amperes dc all locations
-
Trip Release Method
thermal all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 3000.0 dc all locations
-
Trip Release Characteristic
time delay all locations
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
-
Storage Type
general purpose warehouse
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.906 inches minimum and 0.968 inches maximum
-
Special Features
parallel connecting bar accross terminas
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 28.0 dc all locations
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Fragility Factor
moderately rugged
-
Actuator Function
reset