NSN: 5925-01-089-3726

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    2 quick disconnect,male

  • Body Length

    2.000 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    1.840 inches nominal

  • Pole Quantity

    1

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    instantaneouss

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Terminal Type

    tab,solder lug

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Thread Series Designator

    unc

  • Body Width

    0.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    1 alarm

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...