NSN: 5925-01-092-6290

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

  • Frequency In Hertz

    60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.600 maximum at 200 pct

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Boss Height

    0.099 inches minimum and 0.161 inches maximum

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Specification/Standard Data

    81349-mil-c-55629/7 government specification

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.629 inches minimum and 1.691 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...