NSN: 5925-01-092-6395
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac fifth location
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac fourth location
-
Storage Type
general purpose warehouse
-
Switch Current Rating And Type In Amps
10.0 ac
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Boss Height
0.135 inches minimum and 0.165 inches maximum
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Pole Quantity
6
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
-
Switch Contact Arrangement
single pole, double throw
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac sixth location
-
Body Width
4.515 inches maximum
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Switch Voltage Rating And Type In Volts
120.0 ac
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
External Actuator Linkage Arrangement
one, two, three, four, five, and six linked
-
Terminal Type And Quantity
12 threaded stud
-
Inclosure Protection Type For Which Designed
shockproof and corrosion resistant and moisture resistant and vibrationproof
-
Unpackaged Unit Weight
22.200 ounces
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Frequency In Hertz
400.0 all locations
-
Switch Terminal Type
pin
-
Switch Location And Position Designation
internal at pole four and internal at pole five and internal at pole six
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac third location
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Mounting Surface To Terminal End Distance
2.625 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Manual Actuator Type And Quantity
6 toggle
-
Mounting Facility Type And Quantity
12 threaded hole
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location