NSN: 5925-01-093-3388

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 threaded hole and 2 unthreaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Terminal Type And Quantity

    4 compression

  • Body Style

    multipole-single actuator type

  • Trip Release Method

    thermal-magnetic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.380 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.380 inches nominal

  • Body Width

    2.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Specification/Standard Data

    81348-w-c-375/11 government specification

  • Body Height

    3.380 inches nominal

  • Actuator Function

    trip-reset

  • ~1

    data on certain environmental and performance re

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Body Length

    6.310 inches nominal

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...