Technical Characteristics

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Frequency In Hertz

    60.0

  • Test Data Document

    81348-w-c-375 specification

  • Terminal Type And Quantity

    4 compression

  • Specification/Standard Data

    81348-w-c-375/17 government specification

  • Body Length

    6.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 slot

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Body Style

    9b multipole-single actuator type

  • Mounting Slot Width

    0.094 inches nominal

  • Body Width

    2.750 inches nominal

  • Body Height

    3.375 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches nominal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...