NSN: 5925-01-097-3633

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 1.900 maximum at 200 pct all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Frequency In Hertz

    400.0

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    unc

  • Specification/Standard Data

    81349-mil-c-55629/4 government specification

  • Body Length

    2.510 inches maximum

  • Body Width

    1.437 inches minimum and 1.563 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one and two linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...