NSN: 5925-01-098-9982

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 wire hook

  • Thread Series Designator

    unef

  • Iii Unpackaged Unit Weight

    3.600 ounces

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Iii Special Handling Feature

    magnetic

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Iii Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Iii Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Case Material

    metal

  • Frequency In Hertz

    50.0 or 60.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct and 0.700 maximum at 200 pct all locations

  • Actuator Position Designation

    between pole one and two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Body Width

    1.281 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...