NSN: 5925-01-104-4624
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Body Height
1.500 inches maximum
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches nominal
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Manual Actuator Type And Quantity
1 push-pull
-
Bushing Length
0.281 inches nominal
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Body Style
multipole-single actuator type
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations and 25.0 amperes dc all locations
-
Terminal Type And Quantity
6 tab w/screw
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
Case Material
plastic
-
Body Width
0.850 inches nominal
-
Trip Release Method
thermal all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations and 28.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations and 2500.0 dc all locations