Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Specification/Standard Data

    81349-mil-c-55629/5 government specification

  • Body Length

    2.479 inches minimum and 2.510 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Mounting Surface To Terminal End Distance

    2.522 inches minimum and 2.553 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.600 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...