NSN: 5925-01-107-6623
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Unpackaged Unit Weight
3.250 ounces
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
-
Body Length
2.189 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.810 inches nominal
-
Bushing Length
0.250 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
0.760 inches maximum
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Trip Delay Time In Seconds Per Rated Continuous Current
14.000 minimum at 200 pct single location and 36.000 maximum at 200 pct single location
-
Terminal Type And Quantity
2 tab w/screw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Case Material
plastic