NSN: 5925-01-107-8009
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.650 minimum at 200 pct single location and 0.080 minimum at 500 pct single location and 1.500 maximum at 400 pct single location and 8.000 maximum at 200 pct single location and 0.150 minimum at 400 pct single location and 0.800 maximum at 500 pct
-
~1
single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Time Per Pole In Seconds
50.000 maximum single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Mounting Surface To Terminal End Distance
1.843 inches nominal
-
Case Material
plastic