NSN: 5925-01-110-3188
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
3.000 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Boss Height
0.150 inches nominal
-
Pole Quantity
4
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2100.0 ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Body Length
2.490 inches nominal
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Surface To Terminal End Distance
2.491 inches maximum
-
Mounting Facility Type And Quantity
8 threaded hole
-
Thread Quantity Per Inch
32
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
4 toggle
-
External Actuator Linkage Arrangement
one,two,three,and four linked
-
Internal Trip Release Configuration
series trip
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 12.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
400.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
8 threaded stud