NSN: 5925-01-112-8707

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    3.750 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Pole Quantity

    5

  • Mounting Facility Type And Quantity

    10 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc fourth location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    any acceptable

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    any acceptable

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.950 maximum at 200 pct fifth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 4.000 maximum at 200 pct first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 4.000 maximum at 200 pct second location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    10 threaded stud

  • Body Length

    2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Boss Height

    0.150 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc first location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc third location

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes dc fifth location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    5 toggle

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one and two linked and three, four, and five linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.950 maximum at 200 pct fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.950 maximum at 200 pct third location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...