NSN: 5925-01-113-2911
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 250.0 ac all locations
-
Features Provided
sliding bar interlock
-
Reset Method
manual
-
Boss Height
0.150 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.900 minimum at 400 pct all locations and 60.000 maximum at 200 pct all locations and 8.000 maximum at 400 pct all locations and 10.000 minimum at 200 pct all locations and 0.600 minimum at 600 pct all locations and 2.500 maximum at 600 pct all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Body Width
1.500 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Manual Actuator Type And Quantity
2 toggle
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Inclosure Protection Type For Which Designed
shock resistant and hermetically sealed and vibration resistant
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac second location
-
Ultimate Trip Time Per Pole In Seconds
80.000 minimum all locations and 650.000 maximum all locations
-
Unpackaged Unit Weight
7.400 ounces
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations and 1000.0 ac all locations
-
Terminal Type And Quantity
4 threaded stud
-
External Actuator Linkage Arrangement
one and two linked
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location