Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    11.0 amperes dc single location

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Unpackaged Unit Weight

    4.250 ounces

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    2.997 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct single location and 0.500 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...