NSN: 5925-01-116-5463

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt water resistant and shock resistant and vibration resistant

  • Special Features

    includes inertial delay

  • Frequency In Hertz

    50.0 or b60.0

  • Terminal Type And Quantity

    2 threaded stud

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct

  • Switch Terminal Type

    quick disconnect,male

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Thread Series Designator

    unc

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...