NSN: 5925-01-118-3866

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.376 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Ultimate Trip Time Per Pole In Seconds

    0.350 minimum all locations and 1.400 maximum all locations

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Trip Release Ambient Temp Rating

    -54.0 deg celsius minimum all locations and 71.0 deg celsius maximum all locations

  • Reset Method

    manual

  • Body Height

    1.900 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof and vibrationproof

  • Storage Type

    general purpose warehouse

  • Body Length

    2.060 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Special Features

    terminals seperated by barriers; amper rating marked on actuator

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    160.0 all locations

  • Actuator Position Designation

    at pole two

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...