NSN: 5925-01-121-6280

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Body Width

    0.750 inches nominal

  • Actuator Position Designation

    at pole one

  • Switch Terminal Type

    turret

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Ultimate Trip Time Per Pole In Seconds

    80.000 maximum single location

  • Frequency In Hertz

    60.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Boss Height

    0.140 inches nominal

  • Body Length

    2.500 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 400 pct single location and 2.000 maximum at 400 pct single location

  • Nominal Thread Size

    0.138 inches

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...