NSN: 5925-01-123-5201

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.844 inches nominal

  • Body Width

    3.096 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole and

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    60.000 maximum at 200 pct all locations

  • Body Style

    8c multipole-multiple actuator type

  • Mounting Slot Width

    0.164 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    3 slot

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Frequency In Hertz

    400.0 all locations

  • Iii Unpackaged Unit Weight

    3.000 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...