  • Body Style

    single pole type

  • Body Length

    0.750 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.707 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Method

    thermal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.469 inches

  • Special Features

    ampere marked on actuator

  • Unpackaged Unit Weight

    1.500 ounces

  • Bushing Length

    0.250 inches nominal

  • Body Width

    0.562 inches nominal

  • Pole Quantity

    1

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac and 3.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac and 2000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    corrosion resistant and sand resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Frequency In Hertz

    400.0

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.