NSN: 5925-01-126-2640

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    relay trip first location

  • Maximum Continuous Load Current Rating Per Pole

    5.5 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc first location

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Body Style

    multipole-single actuator type

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Circuit Protection Type

    overvoltage first location

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    any acceptable all locations

  • Internal Trip Release Configuration

    series trip w/dual rating second location

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac second location

  • Special Features

    tapped for 2.75 amp

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc first location

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Body Width

    1.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    any acceptable all locations

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    63.0 second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.