NSN: 5925-01-126-5278

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    160.0 deg fahrenheit maximum single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Nonturn Device Radius

    0.375 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.218 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant and sand resistant and explosion proof and vibrationproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Nominal Thread Size

    0.469 inches

  • Nonturn Device Width

    0.078 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Body Length

    0.750 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • Body Width

    0.562 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nonturn Device Length

    0.047 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 6000.0 dc single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...