NSN: 5925-01-126-8188

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    2.200 ounces

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.645 inches minimum and 1.675 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    18.0 amperes ac single location

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Special Features

    black with white markings on handle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.