NSN: 5925-01-127-0620
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
1.515 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Pole Quantity
2
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
4 threaded hole
-
Iii Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Auxiliary Switch Function And Quantity
1 alarm
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
iso m
-
Body Length
2.490 inches nominal
-
Body Style
8c multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Iii Fragility Factor
moderately rugged
-
Boss Height
0.150 inches nominal
-
Mounting Surface To Terminal End Distance
2.475 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
fungus resistant and dustproof
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Iii Unpackaged Unit Weight
14.000 ounces
-
Terminal Type And Quantity
4 threaded stud
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Reset Method
manual
-
Manual Actuator Type And Quantity
2 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
3.0 millimeters
-
Thread Pitch In Millimeters
0.50
-
Switch Location And Position Designation
internal at pole two