NSN: 5925-01-127-7608

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 push-pull

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Specification/Standard Data

    96906-ms3320 government standard

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Terminal Type And Quantity

    2 screw

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Body Length

    0.781 inches maximum

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Bushing Length

    0.250 inches nominal

  • ~1

    data on certain environmental and performance

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Width

    0.593 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    0.055 pounds

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...