NSN: 5925-01-128-3583

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.150 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    2 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Thread Quantity Per Inch

    32

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Case Material

    plastic

  • Body Width

    0.750 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Style

    12a single pole type

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Iii Special Handling Feature

    magnetic

  • Iii Storage Type

    general purpose warehouse

  • Thread Series Designator

    unc

  • Iii Unpackaged Unit Weight

    3.700 ounces

  • Frequency In Hertz

    50.0 or 60.0 single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt water resistant and shock resistant and vibration resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...