NSN: 5925-01-129-6220

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac second location

  • Trip Release Characteristic

    time delay second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Frequency In Hertz

    400.0 second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct first location and 9.000 maximum at 200 pct first location

  • Body Length

    1.562 inches maximum

  • Body Width

    1.987 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    12.0 dc third location

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac first location

  • Thread Series Designator

    unef

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac second location

  • Unpackaged Unit Weight

    5.400 ounces

  • Terminal Type And Quantity

    6 wire hook

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct second location and 9.000 maximum at 200 pct second location

  • Internal Trip Release Configuration

    relay trip third location

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Internal Trip Release Configuration

    series trip first location

  • Trip Release Characteristic

    time delay first location

  • Actuator Position Designation

    at pole two

  • Bushing Length

    0.380 inches maximum

  • Trip Release Characteristic

    instantaneous third location

  • Mounting Facility Type And Quantity

    2 threaded bushing w/panel seal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...