Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct third location and 1.500 maximum at 200 pct third location

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac first location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac second location

  • Frequency In Hertz

    60.0 third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.024 maximum at 200 pct fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct second location and 1.500 maximum at 200 pct second location

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Case Material

    plastic

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac third location

  • Circuit Protection Type

    undervoltage fourth location

  • Frequency In Hertz

    60.0 first location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Frequency In Hertz

    60.0 second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip second location

  • Body Width

    2.250 inches maximum

  • Internal Trip Release Configuration

    relay trip fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 dc fourth location

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Boss Height

    0.150 inches nominal

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Circuit Protection Type

    overcurrent second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct first location and 1.500 maximum at 200 pct first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...