NSN: 5925-01-130-1800

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct and 15.000 maximum at 200 pct third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 10.000 maximum at 200 pct second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 10.000 maximum at 200 pct first location

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc third location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac first location

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Boss Height

    0.140 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Body Width

    2.250 inches nominal

  • Body Length

    2.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac second location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Case Material

    plastic

  • Body Style

    8c multipole-multiple actuator type

  • Terminal Type And Quantity

    8 threaded stud

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    9.500 ounces

  • Frequency In Hertz

    60.0

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip first location

  • Internal Trip Release Configuration

    relay trip third location

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 1000.0 dc all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...