NSN: 5925-01-131-1695
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Duty Cycle
continuous single location
-
Body Length
1.781 inches nominal
-
Thread Series Designator
uns
-
Case Material
plastic
-
Ultimate Trip Time Per Pole In Seconds
0.003 nominal single location
-
Trip Release Method
magnetic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
300.0 single location
-
Reset Method
manual
-
Circuit Protection Type
overcurrent single location
-
Nominal Thread Size
0.468 inches
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Body Width
0.656 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Mounting Facility Type And Quantity
1 threaded stud
-
Trip Release Characteristic
instantaneous single location
-
Mounting Surface To Terminal End Distance
1.669 inches nominal
-
Thread Tolerance Class
2a external
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location