NSN: 5925-01-133-1594

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • End Item Identification

    item is used in an electrical power distribution panel on a 32 ft. coast guard vessel

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Slot Width

    0.164 inches nominal

  • Body Width

    2.038 inches minimum and 2.102 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct and 100.000 maximum at 200 pct

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 threaded stud

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Body Height

    2.828 inches nominal

  • Body Style

    multipole-multiple actuator type

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.