NSN: 5925-01-137-3749

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.280 inches nominal

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Width

    0.430 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.550 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Thread Quantity Per Inch

    27

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    300.0 milliamperes ac single location and 300.0 milliamperes dc single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1.8 ac single location and 1.8 dc single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.470 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Body Length

    0.750 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Actuator Function

    reset

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...