NSN: 5925-01-138-9588

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    2.200 ounces

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Internal Trip Release Configuration

    series trip

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Boss Height

    0.130 inches nominal

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Case Material

    plastic

  • Body Length

    2.000 inches nominal

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    unc

  • Special Features

    actuator black with white markings

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Switch Terminal Type

    quick disconnect,male

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and 10.000 maximum at 200 pct

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.138 inches

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Width

    0.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...