NSN: 5925-01-142-0333

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Terminal Type And Quantity

    6 compression

  • Body Width

    4.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Style

    13b multipole-single actuator type

  • Body Length

    6.312 inches nominal

  • Body Height

    3.188 inches nominal

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Iii End Item Identification

    5895-01-077-6249

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Iii Special Handling Feature

    magnetic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct and 125.000 maximum at 200 pct all locations

  • Frequency In Hertz

    60.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...