NSN: 5925-01-142-0334

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    0.850 inches nominal

  • Unpackaged Unit Weight

    1.500 ounces

  • Manual Actuator Type And Quantity

    1 push button

  • Body Width

    0.660 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Case Material

    plastic

  • Thread Quantity Per Inch

    28

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Bushing Length

    0.500 inches nominal

  • Thread Series Designator

    unef

  • Frequency In Hertz

    60.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac single location and 6.0 amperes dc single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Mounting Surface To Terminal End Distance

    1.815 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2000.0 dc single location

  • Body Length

    1.375 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...