NSN: 5925-01-145-5328

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Actuator Function

    trip-reset

  • Body Width

    3.015 inches maximum

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct second location and 9.000 maximum at 200 pct second location

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct first location and 9.000 maximum at 200 pct first location

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Frequency In Hertz

    60.0 first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct third location and 9.000 maximum at 200 pct third location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Frequency In Hertz

    60.0 second location

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Internal Trip Release Configuration

    series trip second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Nominal Thread Size

    0.138 inches

  • Terminal Type And Quantity

    9 threaded stud

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Internal Trip Release Configuration

    series trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc fourth location

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Trip Release Characteristic

    instantaneous fourth location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 fourth location

  • Frequency In Hertz

    60.0 third location

  • Internal Trip Release Configuration

    shunt trip fourth location

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations and 25.0 amperes dc all locations

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Manual Actuator Type And Quantity

    4 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

  • Pole Quantity

    4

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...