NSN: 5925-01-145-9192

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct first location and 8.000 maximum at 200 pct first location

  • Unpackaged Unit Weight

    6.438 pounds

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc first location

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal all locations

  • Body Width

    1.510 inches minimum and 1.530 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Trip Release Characteristic

    instantaneous second location

  • Switch Location And Position Designation

    internal at each pole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Manual Actuator Type And Quantity

    2 toggle

  • Mounting Surface To Terminal End Distance

    2.392 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    35.0 dc second location

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    4 threaded stud

  • Switch Terminal Type

    quick disconnect, male

  • External Actuator Linkage Arrangement

    one and two linked

  • Body Length

    2.480 inches minimum and 2.520 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...