NSN: 5925-01-146-0433

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • End Item Identification

    f16aircombfit

  • Boss Height

    0.150 inches nominal

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Terminal Type And Quantity

    4 threaded stud

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip all locations

  • Unpackaged Unit Weight

    7.400 ounces

  • Thread Series Designator

    unc

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    1.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...